Customization: | Available |
---|---|
Type: | Inverter Air Conditioner |
Capacity: | 9000-24000 BTU |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model No. | R32 9K | R32 12K | R32 18K | R32 24K | ||
Type | heating pump | heating pump | heating pump | heating pump | ||
Control type | remote controller | remote controller | remote controller | remote controller | ||
Cooling capacity | W | 2600(940~3300) | 3400(1000~3770) | 5100(1250-5900) | 6810(1830~7810) | |
Heating capacity | W | 2610(940~3360) | 3420(1000~3810) | 5130(1250-6080) | 6870(1850~7930) | |
SEER | W/W | 6.3 | 6.1 | 6.1 | 6.5 | |
Energy Class | A++ | A++ | A++ | A++ | ||
SCOP (Average) | W/W | 4.0 | 4.0 | 4.0 | 4.1 | |
Energy Class(Average) | A+ | A+ | A+ | A+ | ||
Annual energy consumption | Cooling | kwh/a | 144 | 195 | 293 | 366 |
Average | kwh/a | 735 | 840 | 1575 | 1878 | |
Moisture removal | Liters/h | 1.00 | 1.2 | 1.5 | 1.8 | |
Indoor sound power(S/H/M/L/Mute) | dB(A) | 50/47/43/35/32 | 50/47/43/35/32 | 53/50/47/43/36 | 54/51/48/44/40 | |
Outdoor sound power | dB(A) | 60 | 60 | 65 | 67 | |
Indoor sound pressure(S/H/M/L/Mute) | dB(A) | 40/37/33/25/22 | 40/37/33/25/22 | 43/41/38//35/27 | 44/41/38/34/30 | |
Outdoor sound pressure | dB(A) | 50 | 50 | 55 | 57 | |
Electrical Data | ||||||
Power supply | 220-240V~/50Hz/1P | 220-240V~/50Hz/1P | 220-240V~/50Hz/1P | 220-240V~/50Hz/1P | ||
Voltage Range | V | 165~265 | 165~265 | 165~265 | 165~265 | |
Operating current | Cooling | A | 4.6(1.2~8.0) | 5.8(1.5~9.0) | 8.1(1.7~12.0) | 11.3(2.3~12.9) |
Heating | A | 4.1(1.2~9.0) | 4.7(1.5~10.0) | 7.1(1.7~13.0) | 9.7(2.3~13.7) | |
Power consumption | Cooling | W | 800(240~1380) | 1130(290~1500) | 1579(330-2350) | 2226(410~2800) |
Heating | W | 699(240~1552) | 922(290~1720) | 1382(340-2540) | 1903(420~3000) | |
Refrigerating System | ||||||
Refrigerant type/Charge/GWP/CO2 equivalent | R32/0.53kg/675/0.358tonnes | R32/0.55kg/675/0.372tonnes | R32/0.92kg/675/0.621tonnes | R32/1.06kg/675/0.716tonnes | ||
Compressor | Type | Rotary | Rotary | Rotary | Rotary | |
MFG | GMCC | GMCC | SANYO | SANYO | ||
Indoor air circulation Cooling/heating | m3/h | 420/420 | 550/550 | 800/800 | 970/980 | |
Indoor fan type | Cross Flow | Cross Flow | Cross Flow | Cross Flow | ||
Outdoor fan type | Propeller fan | Propeller fan | Propeller fan | Propeller fan | ||
Outdoor air circulation | m3/h | 1900 | 1900 | 2600 | 3000 | |
Connections | ||||||
Connecting Wiring | Core x Size | 4×0.75mm² | 4×0.75mm² | 4×0.75mm² | 4×0.75mm² | |
Expension device | Capillary | Capillary | Electronic expansion valve | Electronic expansion valve | ||
Connecting Pipe | Gas | Inches | 3/8" | 3/8" | 3/8" | 1/2" |
Liquid | Inches | 1/4" | 1/4" | 1/4" | 1/4" | |
Others | ||||||
Application area | m² | 9~16 | 14~22 | 20~35 | 27~45 | |
Max. refrigerant pipe length | m | 25 | 25 | 25 | 25 | |
Max. difference in level | m | 10 | 10 | 10 | 10 | |
Operation temperature range | ºC | 16-31 | 16-31 | 16-31 | 16-31 | |
Ambient temperature range | Outdoor | ºC | Cooling:-15-53/Heating:-20-30 | Cooling:-15-53/Heating:-20-30 | Cooling:-15-53/Heating:-20-30 | Cooling:-15-53/Heating:-20-30 |
Indoor | ºC | Cooling:17-32/Heating:0-30 | Cooling:17-32/Heating:0-30 | Cooling:17-32/Heating:0-30 | Cooling:17-32/Heating:0-30 | |
Net dimensions | Indoor | mm | 698×255×190 | 777×250×201 | 910×294×206 | 1010×315×220 |
(W x H x D) | Outdoor | mm | 777×498×290 | 777×498×290 | 853×602×349 | 920×699×380 |
Net weight | Indoor | kg | 6.5 | 8 | 10 | 13 |
Outdoor | kg | 22 | 22 | 35 | 40 | |
Packing dimensions | Indoor | mm | 764×325×257 | 850×320×275 | 979×372×277 | 1096×390×297 |
(W x H x D) w/o pipe | Outdoor | mm | 818×520×325 | 818×520×325 | 890×628×385 | 960×732×400 |
w/i pipe | Outdoor | mm | 818×520×325 | 818×520×325 | 890×628×385 | 960×732×430 |
Gross weight | Indoor | kg | 8.5 | 10.5 | 13 | 16 |
Outdoor | kg | 25(w/o pipe) 26(w/i pipe) |
25(w/o pipe) 26(w/i pipe) |
38(w/o pipe) 39(w/i pipe) |
43(w/o pipe) 46(w/i pipe) |
|
Loading Capacity w/o pipe | 20'/40'GQ/40'HQ | 149/303/330 | 128/259/310 | 83/177/203 | 63/133/142 | |
Loading Capacity w/i pipe | 20'/40'GQ/40'HQ | 149/303/330 | 128/259/310 | 83/177/203 | 63/133/142 |